- Other Auto Parts[2]
- Floor Heating Systems & Parts[1]
- Other Electrical Equipment[3]
- Flow Switches[1]
- Other Switches[1]
- Capacitors[2]
- Water Treatment[3]
- Boiler Parts[1]
- Engine Parts[8]
- Water Filter[2]
- Flow Meters[10]
- Instrument Parts & Accessories[3]
- Level Measuring Instruments[10]
- Gauges[2]
- Other Measuring & Analysing Instruments[1]
- Other Pressure Measuring Instruments[3]
- Pressure Gauges[6]
- Pressure Sensors[1]
- Pressure Transmitters[1]
- Temperature Instruments[2]
- Testing Equipment[3]
- Hydraulic Parts[1]
- Screwdriver[3]
- Wrench[7]
- Contact Person : Ms. Deng XuJuan
- Company Name : Xian Ding Xing Automation Engineering Co., Ltd.
- Tel : 0086-029-68813631
- Fax : 0086-029-88611700
- Address : Shaanxi,Xi'an,Room 5019, Area 1, Dongguang Building, No. 78 Southern Section of West Ring Road,Lianhu Dist.
- Country/Region : China
- Zip : 710000
Related Product Searches:Target Flow controller,High Quality,flow control medical, gas flow control,HFS
HFS Target Flow controller with target sensors can be used for water or other fluid loop cooling system. Controller with adjustable settings
Specifications
No. | Range L / min | Switching difference l / min | Repeatability error L / min | Pipe diameter | Target | The maximum allowable pressureMPa | Weight kg | |
in | mm | |||||||
1 | 20~48 | 8 | 1.1 | 1 | 25 | 1 | 1.6 | 0.5 |
2 | 34~100 | 10 | 2.6 | 5/4 | 32 | 1 | ||
3 | 65~160 | 14 | 3.8 | 3/2 | 40 | 1 | ||
4 | 120~280 | 26 | 6.4 | 2 | 50 | 1 | ||
5 | 40~140 | 18 | 4.0 | 2 | 50 | 2 | ||
6 | 210~550 | 18 |
| 5/2 | 70 | 1 | ||
7 | 110~340 | 15 |
| 5/2 | 70 | 2 | ||
8 | 380~750 | 20 |
| 3 | 80 | 1 | ||
9 | 180~470 | 18 |
| 3 | 80 | 2 | ||
10 | 115~220 | 20 |
| 3 | 80 | 3 | ||
11 | 350~920 | 20 |
| 4 | 100 | 2 | ||
12 | 210~590 | 20 |
| 4 | 100 | 3 | ||
13 | 380~1200 | 40 |
| 5 | 125 | 3 | ||
14 | 550~1800 | 80 |
| 6 | 150 | 3 |
B. Electrical performance
SPDT switch Working state: Flow increased first switching value, the connection terminal connected to 0-cb; flow down to the next switch value , 0-ck connected.
C. Installation
Tighten the controller in specific interface of the pipeline.Medium flow direction should be accordance with direction of the arrow on shell.The target of controller should vertically with Flow direction of medium In front of Controller requires 10 times length of diameter of the pipe guiding straight channel.Open the controller casing, according to wiring diagram wiring, and then install the casing.Target Flow controller